Search results
1251
[Page extract]
ASTM D6117-18
ASTM D6117 covers the evaluation of fastener use with “as manufactured” plastic lumber and shapes through the use of two different testing procedures:
1252
[Page extract]
BS ISO 6133
BS ISO 6133 specifies five methods of calculating, after testing, the tear strength and the adhesion strength of vulcanized rubber or fabrics coated with or adhered to rubber or plastics.
1253
[Page extract]
BS EN ISO 80369-20
These standards describes the methods for testing the performance of 6% Luer lock fittings including assembly, leak tightness, stress cracking, and separation force.
1254
[Page extract]
*corp Mastercard CQM: ID-1
Mastercard CQM requirement covers Peel Strength Test (TM-412 #8120#) and Advanced Peel Strength Test (TN-424 #8240#). Methods are based around ISO 10373-1 to determine the peel strength between 2 layers of an ID or security card.
1255
[Page extract]
BS EN 1707
Syringes, Conical fittings (syringes), Injection instruments, Locking and locating devices, Fitting, Pipe fittings, Medical equipment, Medical instruments, Blood transfusion equipment, Dimensions, Dimensional tolerances, Performance testing, Leak tests,
1256
[Page extract]
ASTM D412-16
ASTM D412 is a test standard for testing the tensile stress-strain properties of thermoset rubbers and thermoplastic elastomers. The standard is divided into two test methods.
1257
[Page extract]
ASTM D6742 / D6742M
ASTM D6742 is the standard test method for tensile and compression testing of filled-hole polymer matrix composite laminates. It provides instructions for modifying open-hole tension and compression test methods to determine filled-hole tensile and com
1258
[Page extract]
BS EN ISO 9626
This International Standard specifies the dimensions, surface and mechanical properties of normal- and thin-walled tubing of designated metric sizes 3,4 mm to 0,3 mm, and of extra-thin-walled tubing of designated metric sizes 2,1 mm to 0,6 mm.
1261
[Page extract]
Young's modulus
Measure how stiff or elastic a material is under tension or compression with Young’s modulus testing. Universal testing systems provide reliable modulus of elasticity measurements for compliance with global standards like ISO 527 and ASTM D638.
1262
[Page extract]
Needle penetration and drag testing assess the force required to insert a needle into a material and the friction experienced during this process. This test ensures that syringes perform reliably, reducing risks to patients and healthcare providers.
1263
[Page extract]
Baumann tear test
- slit cut laterally in the centre of sample; used to test the tear strength of leather
1264
[Page extract]
Ultimate Tensile Strength
What it is, how to measure it, and why it matters
Ultimate tensile strength (UTS) is a critical property used to determine how materials behave under tension. It defines the maximum stress a material can withstand before breaking.
1265
[Page extract]
Abrasion
Abrasion is the surface wear caused by rubbing with another material. The consumer would expect textiles and other products to withstand a certain amount of deterioration.
1266
[Page extract]
Government
The general government sector covers institutions and public bodies where regulations and standards must be strictly adhered to.
1267
Accessory
Dual Footswitches (non-locking type) for pneumatic grips
Mec205-1
Pneumatic grips are the ideal choice when performing tensile tests on sensitive materials that have a tendency to slip or break at point of clamping.
Mec205-1:
Non-locking dual footswitches open the jaws of the pneumatic grip by pressing the foot pedal…
1268
Accessory
Self-levelling Compression Plate Steel - 196 mm, 25 kN, QC-20 fitting
MecS223k-196
MecS223k - 196mm diameter:
Self-levelling allows exact parallelism to be set between the upper and lower plates.. ideal for those applications where it is critical to accurately measure the deformation of a sample.
The MecS223 range of hardened steel…
1269
Accessory
Scissor Grip, 20 kN, QC-20 or QC-32 fitting
Mec11-20
MEC11-20 (Body only) :
Scissor-action grip rated to 20 kN fitted with either QC-20 or QC-32 connection.
Locking function allows the grip to remain open when inserting a specimen.
Spring tension provides enough clamping force to prevent the specimen…
1270
Accessory
Float glass plates (10 pieces), 2" x 8" for FINAT 2 Peel Table
PSV15030
A set of 10 pieces of 2" wide x 8" long (51 x 203mm) float-glass plates. Used to mount adhesive specimens on when testing tensile peel strength to the requirements of FINAT and other standards.
For use with the FINAT 2 Assisted Peel Table - part number…
1271
Accessory
Medium Vice Grip - Single Action, 1 kN, 30 mm opening, QC-20 fitting
Mec240k-S30
MEC 240k-S30 (body only) :
A Medium Single-action Vice Grip allowing one jaw to be set in a position to align a test specimen around the central axis. The other jaw is freely adjustable to mechanically clamp the specimen in place.
Rated to 1 kN in…
1272
Accessory
Self-levelling Compression Plate Steel - 116 mm, 25 kN, QC-20 fitting
MecS223k-116
MecS223k - 116mm diameter Self-levelling Compression Plate:
Self-levelling allows exact parallelism to be set between the upper and lower plates.. ideal for those applications where it is critical to accurately measure the deformation of a sample.
The…
1273
Accessory
Large Single-action Vice Grip, rubber-faced, 2 kN, QC-20 fitting
432-267-V01
A Large Single-action Vice Grip featuring one fixed jaw and one jaw as freely adjustable to mechanically clamp the specimen in place.
Rated to 2 kN in tension with rubber-faced jaws of 78mm wide x 28mm high having an opening of 0-9mm. Provides excellent…
1274
Accessory
Lightweight Mini Vice Grip, 5 N, M6
432-281
By virtue of its spring loaded clamping action the Lightweight Mini Vice Grip is ideal for testing ultra low forces.
Weighing only 30 g it holds specimens without the need to tighten jaws by a thread, which may damage low-capacity loadcells or even the…
1275
Accessory
Cable Cam Grip (large serrated), 5 kN, M10 or M12
432-108
Designed for holding insulated cables and wire. The sample is secured by the serrated cam, which self-tightens as load is applied and minimises the chance of sample slippage.
The grip body features a clearance hole and is supplied with an M10 and M12…