Search results
1301
[Page extract]
BS EN ISO 13127
This standard is only to verify that panel-tested closures with minor modifications are still compliant, by applying mechanical tests as more economical than further full panel tests with children and with adults.
1302
Event
Child Resistant Closure Torque Testing
Medical, Pharmaceutical and Chemical Packaging takes product safety seriously.
1303
[Page extract]
BS EN 13411-3
This European Standard deals with the requirements for ferrules for the ferrule-securing of eyes and endless loops - it applies to slings and assemblies using steel wire ropes for general lifting applications up to and including 60mm diameter conforming
1304
[Page extract]
ISO 16047
ISO 16047:2005 specifies the conditions for carrying out torque/clamp force tests on threaded fasteners and related parts.
1305
[Page extract]
BS EN 843-1
EN843-1 describes methods for determining the nominal flexural strength of advanced monolithic technical ceramic materials at ambient temperature.
1306
[Page extract]
BS EN 3841-509
This standard specifies a method of determining the forces required to insert and extract the contact pin into and out of the terminal socket of the signal contact. It shall be used together with EN 3841-100.
1307
Event
Wine & Spirits: Pull Tab & Twist Cap Testing
Canned wine and seltzer drinks have a clear upside that makes their popularity soar: Convenience. As well as being lighter to carry, less potentially fragile, eliminating the corkscrew, and even a glass makes it ideal for social gatherings.
1308
[Page extract]
ASTM F458-13
This practice covers nondestructive testing of individual wire bonds made by either ultrasonic, thermal compression or thermosonic techniques.
1309
[Page extract]
BS EN ISO 3376
This International Standard specifies a method for determining the tensile strength , elongation at a specified load and elongation at break. It is applicable to all types of leather
1310
Event
Mechanical Performance Testing of Medical Devices Webinar
A hands-on Force and Torque how-to demonstration event.
1311
[Page extract]
TAPPI T 402
Standard conditioning and testing atmospheres for paper, board, pulp handsheets, and related products, Test Method TAPPI/ANSI T 402 sp-13
1312
[Page extract]
ASTM E1012-12e1
It has been shown that bending stresses that inadvertently occur due to misalignment between the applied force and the specimen axes during the application of tensile and compressive forces can affect the test results.
1313
[Page extract]
ASTM C1161
This test method covers the determination of flexural strength of advanced ceramic materials at ambient temperature. Four-point and three-point loadings with prescribed spans are the standard.
1314
Event
Introduction to consumer packaging testing
In the competitive world of consumer goods, damaged packaging isn't just a financial setback—it can tarnish your brand's reputation.
1315
[Page extract]
ASTM E345-93
Tension tests provide information on the strength and ductility of materials under uniaxial tensile stresses. This information may be useful in comparisons of materials, alloy development, quality control, and design.
1316
[Page extract]
BS EN 1465
Specifies a method for determining the tensile lap-shear strength of bonded assemblies when tested on a standard specimen and under specified conditions of preparation and testing.
1317
[Page extract]
ISO 8510-1
Particularly suitable for use with less flexible adherends for which a 180 ° peel test is not suitable because the adherends crack, break or delaminate. A bonded assembly of two adherends is prepared using the adhesive under test.
1318
[Page extract]
TAPPI T 556
This procedure is used to measure the bending resistance of paper and paperboard in the machine and cross machine directions, by determining the bending resistance in mN of a 38mm (1.5in) wide vertically clamped sample, at 15o or 7.5o deflection.
1319
[Page extract]
BS EN ISO 376
BS EN ISO 376:2011 looks at the calibration of force-proving instruments used for the static verification of uniaxial testing equipment. These include tension and compression testing machines.
1320
[Page extract]
BS EN ISO 80369-7
This part of ISO 80369 specifies dimensions and requirements for the design and functional performance of small-bore connectors intended to be used for connections in intravascular applications or hypodermic connections in hypodermic applications of med
1321
[Page extract]
SAE AS1310B
This SAE Aerospace Standard (AS) is intended for use by those involved in the design of aircraft, missile, or space systems, and their support equipment to define the various type of fastener torque.
1322
[Page extract]
NF S86-604
This document defines the test methods for characterizing metallic watch straps and the corresponding requirements.
1323
Event
Understanding Adhesion Strength: 180 Degree Peel Test
Across many households and industries, consumers have developed a strong preference for and confidence in ‘Duct Tape’ for all types of uses and applications. This is mainly due to the adhesion strength.
1324
[Page extract]
EN 16287
Series of standards, including 16288, 16289, 16290, 16291, 16292, 16293 and others
Dimensions and specifications for a series of bottle finishes, including corks, crown, screw threads, including bottles with internal pressure.
1325
[Page extract]
ASTM E2658-15
These practices cover procedures and requirements for the calibration and verification of testing machine speed by means of standards calibration devices