Sensor
Sensors - Helixa
Torque sensors
The HTC range of interchangeable torque sensors are specially adapted for the Helixa test system. Plug and play for automatic calibration with availability to suit all requirements in capacities from 0.1 N.m (0.9 lbf.in) to 6 N.m (50 lbf.in…
1002
Accessory
Co-efficient of Friction (COF) Sled for ASTM D1894 and ISO 8295, 200g (foam), FPT-H1
432-633
A neoprene-faced sled with magnetic grips, for testing coefficient of friction of paper samples to TAPPI T549. Supplied with rigid and extensible links.
For use on the FPT-H1 Friction Tester.
1003
Accessory
QC Type M Loadcell Mounting Plate, 13 mm slot c/w M6 bolt for 100 N and 200 N S-beam loadcells
432-452
QC Type M Loadcell Mounting Plate c/w M6 bolt.
Fitted with 13 mm slot to suit 100 N and 200 N S-beam loadcells. The M6 bolt is used to secure the mounting plate onto the loadcell so that a QC type C Male Post (432-284) can be affixed to the loadcell.
1004
Accessory
Orbis and Tornado Mk II/Vortex torque cell accuracy check rig
432-621
This bench-top unit enables the on-site verification of the calibration status of Orbis MkII, Tornado MkII testers, and static torque sensors rated from 1.5 N.m to 10 N.m. Using dead-weight masses, the kit allows you to quickly decide whether or not…
1005
Accessory
QC Type C Adapter, 20 mm M, c/w pin and M6 fixing screws
432-284
QC Male Post 20mm c/w cross-pin, locking collar…
1006
Accessory
Horizontal feet kit for 2.5 kN single-column test stand (on side)
PDV11065
Feet kit for the horizontal operation of a MultiTest motorised test.
When fitted the front panel of the test stand will be on its side for ease-of-operation by the user.
1007
Accessory
Horizontal feet kit for 2.5 kN single-column test stand (on side)
PDV11065
Feet kit for the horizontal operation of a MultiTest motorised test.
When fitted the front panel of the test stand will be on its side for ease-of-operation by the user.
1008
Accessory
Split Mandrel for Stelvin aluminium closure, pneumatic
PDV14181
Suitable for Stelvin aluminium closures.
Pneumatically-operated chuck complete with half-round jaws with wire-eroded faces, for use with Vortex Upper Fixing Plate (432-321). Supplied with pneumatic valves and tubes.
Specify closure diameter when…
1009
Accessory
Lightweight hanger and 50 N slotted mass for verifying FPT 100 N
432-656
A lightweight hanger and an M1 slotted mass of 50N.
For use with the FPT-H1 loadcell calibration checking kit (432-635) to verify the accuracy of HILC 100 N loadcells.
1010
Sensor
Sensors - MultiTest-dV
Force sensors
The MultiTest-dV is a highly flexible tester, which can be configured with either a Touchscreen or Advanced Force Gauge for product testing or an Enhanced Load Sensor for basic materials testing.
AFGA digital force gauge with advanced…
1011
[Page extract]
Compression testing and its applications
Compression testing measures how a material behaves when subjected to forces that reduce its size.
1012
[Page extract]
ASTM F2332-06
This specification covers annular ball bearings intended primarily for use in instrument and precision rotating components.
1013
Event
Tensile Testing: Basics, Tips, & Trends
Have you ever wondered if the seatbelt in your vehicle is strong enough to restrain you in a collision? How about the average person pulling the cork out of a wine bottle?
1014
Case study
Page pull strength test
Requirement
Mecmesin collaborated with a customer to design and develop a force measurement system to determine book binding adhesive strength in retaining individual pages.
1015
[Page extract]
Standards for compressive testing
Key standards for compressive modulus testing include:
1016
[Page extract]
Key test standards for ball burst testing
ASTM D3787 – Constant-rate-of-traverse (CRT) method
This standard outlines a method for determining the bursting strength of
1017
Case study
Closure torque validation
Requirement
The customer had a number of Tornado closure torque testers, and wished to carry out regular validation checks without the need to return the units to either Mecmesin or an approved laboratory.
1018
Case study
Filter test station
Requirement
The following tests were required in a simple-to-use system for a series of tests on automotive filters:
1019
Bundle
Top-load PET bottle CSD non-vented
OmniTest 2.5
BD
Top-load testing (also known as 'column-crush' and 'axial force resistance') is performed mainly on blow moulded, thermoformed or injection moulded plastic containers such as PET (Polyethylene terephthalate) bottles.
1020
[Page extract]
BS EN 13411-3
This European Standard deals with the requirements for ferrules for the ferrule-securing of eyes and endless loops - it applies to slings and assemblies using steel wire ropes for general lifting applications up to and including 60mm diameter conforming
1021
[Page extract]
Introduction to penetration and puncture resistance testing
Penetration and puncture resistance testing are essential for evaluating how well a material can withstand force from sharp, pointed, or blunt objects.
1022
Case study
Sachet compression test
Requirement
To compress six sachets of ketchup or mayonnaise until failure of the packaging occurred.
The peak compressive force was required as the test result.
1023
Case study
Cosmetics tube flip-cap attachment strength
Customised engineering example
Many flip-caps on flat-sealed cosmetics tubes are not designed for removal by the consumer under normal use.
1024
Case study
Stabilised spring testing
Customised engineering example
Our client needed to test a number of small, lightweight springs under compression. To avoid buckling and sideways movement of the springs, a supporting spindle or guide-rod was required.
1025
Case study
Glass syringe Luer lock attachment pull-off
Customised engineering example
Polycarbonate Luer Lock adapters are push-fitted to glass syringe nozzles with a friction fit. Quality assurance demands that they cannot come free under normal use.