Search results
76
Accessory
Eccentric Roller Grip - pyramid (serrated) roller, 1 kN, QC-20 fitting
Mec7-1
MEC7-1 Eccentric Cam Grip
Fitted with a pyramid-faced serrated 50mm wide roller cam. As a load is applied to a specimen the cam self-tightens , spreading the load evenly.
The lever allows for quick insertion and release of specimen to reduce testing…
77
Accessory
Large Circular Bollard Grip, 2 kN, QC-20 fitting
432-271
The Large Circular Bollard Grips is made from steel and is designed for tensile testing up to 2 KN of flexible wire-type materials with a maximum specimen thickness width of 2 mm.
The specimen is wrapped around the bollard and the free end is clamped…
78
Accessory
Small Circular Bollard Grip, 100 N, QC-20 fitting
432-270
The Small Circular Bollard Grips is made from aluminium and is designed for tensile testing up to 100 N of delicate, flexible specimens such as fine threads, wires and yarns, which may break easily when clamped.
The specimen is wrapped around the…
79
Accessory
Lightweight Pneumatic Plane Grip, Single-action, 200 N, pair, QC-20 fitting
Mec94
A pair of versatile Lightweight Pneumatic Plane Grips especially suitable for holding a variety of materials where the tensile force may be low but the material is sensitive to damage or slippage when clamped.
The adjustable screw-driven rod allows…
80
Accessory
Puncture Test Fixture to EN ISO 14477, 500N, QC-20 fitting
MecS511
This EN ISO 14477 Puncture Test Fixture is for testing resistance strength in flexible packaging materials.
The specimen is clamped in the lower specimen holder, which is connected to the base plate of the test stand via a QC-20 female hole.
An upper '…
81
Accessory
Eccentric Roller Grip - Pyramid (serrated) roller, 5 kN, QC-20 fitting
Mec7-5
MEC7-5
Eccentric Cam Grip fitted with a pyramid-faced serrated 50mm wide roller cam. As a load is applied to a specimen the cam self-tightens , spreading the load evenly.
The lever allows for quick insertion and release of specimen to reduce testing…
82
Case study
Prüfung des Flaschenverschlussdrehmoments mit kundenspezifischen Dornen
Anforderung Ein Schlüsselelement bei der Messung des Öffnungs- und Schließmoments zwischen einer Flasche und ihrem Deckel ist die Minimierung von Verzerrungen des Verschlusses durch gleichmäßiges und gleichmäßiges Greifen.
83
[Page extract]
ASTM F2193-02
These specifications and test methods provide standard specifications that specify material, labeling, and handling requirements for components used in surgical fixation of the spinal skeletal system such as metallic spinal screws, spinal plates, and sp
84
[Page extract]
Force Testing
Force testing is a way of determining how an object will react when it is subjected to tensile or compressive loads - either during its normal operation or when being pulled/pushed unti
85
Product
Automatisches Prüfsystem für Reibungs-, Schäl- und Weiterreißtests
FPT-H1
817-001
Das FPT-H1-i ist ein voll ausgestattetes Testsystem, das von auf einem PC ausgeführter Software (Emperor) gesteuert wird.
Präzise und einfach zu verwenden, wurde speziell entwickelt, um den Reibungskoeffizienten, die Abzieh- und Reißfestigkeit einer…
86
Case study
PET screen protector release liner peel testing
Requirement
Manufacturers of products which include a critical screen surface, generally apply a plastic film as protection during assembly, packing and transit to the end customer.
87
[Page extract]
Tools (calibration related)
To maintain consistent performance and accuracy, tools must be checked regularly.
88
[Page extract]
The concentric ring method
The most widely used approach to equibiaxial flexure compression testing is the concentric ring method. A circular specimen is supported on an outer ring and loaded through a smaller, concentric inner ring.
89
Guide
OmniTest™ 5.0 Operation and Installation Manual
Scope
This reference manual covers the operation of an OmniTest-5.0 force test stand, intended for use with Mecmesin enhanced load sensors, extensometer devices and other Mecmesin accessories.
90
[Page extract]
Procedure for tensile testing
While the specifics vary depending on material type and applicable standards, the general procedure includes:
91
[Page extract]
Performing a five-point bend test
Specimen preparation
Cut specimens to the standardised dimensions specified in ASTM D2718.
Ensure surfaces are smooth and free from defects that could affect results.<
92
[Page extract]
Test method and procedure
Preparing specimens
Material selection - Use representative samples from the batch being tested.
Cutting - Prepare specimens to the exact dimensions specified in
93
Case study
Luer and small-bore connector torque testing
Requirement
International standards relevant to small-bore connectors for liquids and gasses in healthcare applications focus on their ease of use and resistance to leakage or mishandling.
94
Case study
Child safety - force to extract lighter
Requirement
The customer manufactures lighters and is currently developing a case/guard designed to increase the safety for children.
95
[Page extract]
Universal testing machines
Our universal testing machines (UTM) are capable of performing a range of tests, including tensile and compression tests, following international and industry-specific standards.
96
Case study
Kindersicherer Verschlussdorn (CRC)
Beispiel für kundenspezifisches Engineering Kindersichere Verschlüsse (Child Resistant Closures, CRC) erfordern eine ausreichende vertikale Kraft, um den CR-Verriegelungsmechanismus zu aktivieren, bevor das Drehmoment angewendet wird.
97
Case study
Einstellbare Drehmomentprüfung der Brille
Beispiel für kundenspezifisches Engineering Adlens stellt adaptive Brillengläser her, bei denen die optische Leistung durch ein seitliches Einstellrad eingestellt wird, das dann entfernt wird.
98
Case study
Prüfung der subkutanen Nadelschärfe
Beispiel für kundenspezifisches Engineering Hypodermische Nadeln werden getestet, um festzustellen, wie ihr Design die Leichtigkeit des Einführens in die Haut, die Schmerzen des Patienten und das Hauttrauma beeinflusst.
99
Case study
Aluminium cap nozzle flexure break-off force
Requirement
A major global supplier of medical gas devices and components required quality control tests to assess part of a new product.
100
Case study
PCB pull and shear test
Requirement
A printed circuit board manufacturer wanted to perform both pull and shear tests of surface-mount solder joints according to IEC 62137-1-1 and -2 standards.