Search results
1177
Case study
Tamper-Proof Closure Test
Requirement
Alcoa required a system to quickly test the tamper-proof rings on soft drink and mineral water closures.
The system had to be easy to operate and allow caps to be loaded quickly.
1178
Case study
Shoulder prostheses tensile testing
Requirement
Mr Keith Borowsky, an eminent orthopaedic surgeon at the University of Brighton Medical School is developing a new orthopaedic prosthesis for shoulder reconstruction.
1179
Case study
Test de pelage sur cartes d'identité
Exigence
Le client produit des cartes d'identité avec une couverture plastifiée.
1180
[Page extract]
BS 7548
Describes requirements and test methods for sterile syringes
with or without needles for single use solely for the injection
of insulin in humans. Covers syringes for use with 40 units of
1181
Case study
Essai sur jouets selon la norme EN 71-1
Exigence
Le client fournit des articles-cadeaux en peluche à des détaillants tels que Clintons.
1182
Case study
Syringe tube pull-off testing
Customised engineering example
Pull-off tensile tests require careful gripping of the separating parts in order to avoid distorting them and therefore artificially weakening the joint.
1183
[Page extract]
Why choose Mecmesin for floating roller peel testing
With decades of experience in materials and force measurement, Mecmesin offers robust and configurable systems that meet industry test standards while adapting to application-specific needs.
1184
[Page extract]
Standards for compressive hardness testing
Internationally recognised standards ensure that compressive hardness tests are accurate, repeatable, and comparable.
1185
[Page extract]
Industrie
Mecmesin est un expert dans la conception et la fabrication d’équipements d'essai de mesuire de force, des matériaux et du couple, avec plus de 40 ans d’expérience dans le domaine.
1186
[Page extract]
PD CEN/TR 17394-1
This document provides requirements for security of attachment for clothing components of infant clothing.
1187
Case study
Fast food tray crush testing
Requirement
As a supplier of fast food trays, the customer needed to make sure that the trays would withstand a certain lateral force without damage to ensure they did not break when being handled and loaded with food.
1188
[Page extract]
Mecmesin solutions for equibiaxial flexure testing
Mecmesin designs and manufactures precision equipment for standards-compliant equibiaxial flexure compression testing, including the concentric ring method. Our systems combine robust mechanical design with advanced control and analysis software.
1189
Case study
Test d'arrachement d'aiguille hypodermique pour seringue
Exigence
Le client, Oxford Instruments, souhaitait effectuer un test d'arrachement destructif afin d'évaluer la force de traction maximale permettant de séparer les 2 composants d'une aiguille hypodermique.
1190
Case study
Cost effective cable strength testing
Customised engineering example
A major manufacturer of wire harnesses and connectors approached us for a cost-effective solution to pull-force test cables with different diameters having direct-bonded joints.
1191
Case study
Toy testing to attachment strength safety standards
Requirement
The customer supplies plush giftware to retailers such as Clintons. Their plush products are manufactured to European toy safety standard BS EN 71-1:1998 (Safety of toys - Part 1: Mechanical and physical properties).
1192
[Page extract]
BS ISO 3597-2
ISO 3597-2 specifies a method for determining the flexural strength of composite rods of circular cross-section made of roving-reinforced resin.
1193
[Page extract]
ASTM F36-15
The ASTM F36 test method covers the determination of the short-time compressibility and recovery at room temperature of sheet-gasket materials, form-in-place gaskets, and in certain cases, gaskets cut from sheets.
1194
Case study
Cosmetics tube flip-cap attachment strength
Customised engineering example
Many flip-caps on flat-sealed cosmetics tubes are not designed for removal by the consumer under normal use.
1195
[Page extract]
Modulus of elasticity formula
Young’s modulus (E) is calculated from the linear portion of a stress-strain curve using this formula:
1196
Case study
Surgical instrument operational torque
Customised engineering example
Endoscopic and laparoscopic surgical instruments are operated by axial and rotating adjustments in the handle, to perform precision movement in the head.
1197
Case study
Removal torque of cap from drug delivery device
Requirement
Global medical technology company Becton Dickinson (BD) needed to assess the torque required to twist off the cap of a drug delivery device.
1198
[Page extract]
Why Mecmesin for material testing solutions
Expertise across diverse sectors
Mecmesin has decades of experience supporting industries from packaging and oral care to pha
1199
[Page extract]
Standards for three-point bend testing
Three-point bend testing is governed by established international standards, including:
1200
Event
Webinar: Adhesion/Peel strength testing
There is a reason people reach for duct tape as a fix for almost everything – adhesion strength.
From busted pipes to ripped furniture, the preference for a solution that “does not easily peel off” is the guiding principle for manufacturers.