Search results
1626
Case study
Karton diagonale kante druckfestigkeit
Beispiel für kundenspezifisches Engineering Neben der axialen Belastungstestung an den Flachseiten von Kartonagen kann die Druckfestigkeit über die gegenüberliegenden Kanten ein wichtiges Maß sein.
1627
[Page extract]
BS EN 1707
Syringes, Conical fittings (syringes), Injection instruments, Locking and locating devices, Fitting, Pipe fittings, Medical equipment, Medical instruments, Blood transfusion equipment, Dimensions, Dimensional tolerances, Performance testing, Leak tests,
1628
[Page extract]
ASTM D695-15
ASTM D695 is a test method used to determine the mechanical properties of unreinforced and reinforced rigid plastics, including high-modulus composites, when loaded in compression at relatively low uniform rates of straining or loading.
1629
[Page extract]
ASTM D3165
This test method is useful in that the joint configuration closely simulates the actual joint configuration of many bonded assemblies.
1630
[Page extract]
BS EN ISO 10555-5
Catheters, Cannulas, Sterile equipment, Parenteral infusion equipment, Medical instruments, Medical equipment, Disposable, Colour codes, Preferred sizes, Diameter, Syringes, Flow rates, Packaging, Tensile testing, Mechanical testing, Testing conditions,
1631
[Page extract]
ASTM D885/D885M-10a
These [comprehensive] test methods cover the testing of industrial filament yarns made wholly of manufactured organic-base fibers, cords twisted from such yarns, fabrics woven from such cords, and products that are made specifically for use in the manuf
1632
[Page extract]
ASTM D412-16
ASTM D412 is a test standard for testing the tensile stress-strain properties of thermoset rubbers and thermoplastic elastomers. The standard is divided into two test methods.
1633
[Page extract]
BS ISO 6133
BS ISO 6133 specifies five methods of calculating, after testing, the tear strength and the adhesion strength of vulcanized rubber or fabrics coated with or adhered to rubber or plastics.
1634
[Page extract]
BS EN ISO 80369-20
These standards describes the methods for testing the performance of 6% Luer lock fittings including assembly, leak tightness, stress cracking, and separation force.
1635
[Page extract]
ASTM C1292
This test method covers the determination of shear strength of continuous fiber-reinforced ceramic composites (CFCCs) at ambient temperature.
1636
[Page extract]
BS EN 1607
This European Standard specifies the equipment and procedures for determining the tensile strength of a product perpendicular to its faces. It is applicable to thermal insulating products.
1639
[Page extract]
Needle penetration and drag testing assess the force required to insert a needle into a material and the friction experienced during this process. This test ensures that syringes perform reliably, reducing risks to patients and healthcare providers.
1640
[Page extract]
Baumann tear test
- slit cut laterally in the centre of sample; used to test the tear strength of leather
1641
[Page extract]
Abrasion
Abrasion is the surface wear caused by rubbing with another material. The consumer would expect textiles and other products to withstand a certain amount of deterioration.
1642
[Page extract]
Government
The general government sector covers institutions and public bodies where regulations and standards must be strictly adhered to.
1643
Accessory
PSV12129 Split mandrel cork grip
PSV12129
A Split Mandrel Grip comprising an outer body with lead-screw and handles. Used for adjustable positioning of half-round jaws having wire-eroded serrated faces.
Designed specifically to grip natural corks of 26-32 mm diameter when testing the release…
1644
Accessory
Compression Plate, Hardened and Ground,12 mm, 10-32 UNF
432-336
Hardened and ground compression plates have a smooth, scratch-proof surface ideal for compression testing on samples that could damage a standard compression plate, such as springs.
12mm diameter having 10-32 UNF female thread.
1645
Accessory
Schraubspannkopf - U-förmig doppeltwirkend, 5 kN, Öffnungsweite 100 mm, Schnellwechsel-Befestigung QC-20
Mec240g-S100
Mec 240g-S100 (nur Korpus):
Ein U-Form Schraubspannkopf mit doppeltwirkender Konstruktion ermöglicht die freie Einstellung der beiden Backen, so dass sie um die Mittelachse ausgerichtet werden können, um Zugversuche an symmetrischen und asymmetrischen…
1646
Accessory
Self-levelling Compression Plate Steel - 196 mm, 50 kN, QC-32 fitting
MecS223g-196
MecS223g - 196mm diameter:
Self-levelling allows exact parallelism to be set between the upper and lower plates - ideal for those applications where it is critical to accurately measure the deformation of a sample.
The MecS223 range of hardened steel,…
1647
Accessory
20 kN Wedge Grip, QC-20 fitting
Mec243-20
MEC 243-20 Wedge Grip (body only):
A multipurpose self-tightening Wedge Grip with a lever arm for rapidly securing and releasing the specimen when testing.
Rated to 20 kN in tension with an opening of 0-16mm depending on the jaw types selected (sold…
1648
Accessory
Digitale Messchieber und Halterungen für manuellem Prüfstand Typ LCP/S.
432-162 V01
Digitale Messchieber und Halterungen zur Montage an den hebelbetätigten Manuellen Prüfstand Typ LCP/S.
Die digitale Anzeige des Messschiebers ist an der beweglichen Traverse des Prüfstands befestigt, so dass die Verschiebung überwacht werden kann. Dies…
1649
Accessory
Lightweight Vice Grip - Double Action, 100 N, Opening 0-8mm, 10-32 UNF
Mec227
MEC 227 (body only):
A Lightweight Vice Grip providing free adjustment of both jaws, allowing them to be aligned around the central axis to accommodate tensile testing of both symmetrical and asymmetrical specimens.
Rated to 100 N in tension with an…
1650
Accessory
QC Type J, lightweight adapter, Ø 20 mm M to 10-32 UNF F c/w pin
432-418
Quick-Change Male Post to Thread Adapter (lightweight)
Fixes directly to the 10-32 UNF screw in anvil plate of test stands or to the 10-32 UNF extension rod connected to loadcells…