Search results
1151
[Page extract]
SAE J1701M
This SAE Information Report is provided as an advisory guide. Individual application discretion is recommended. The content has been presented as accurately as possible, but responsibility for its application lies with the user.
1152
[Page extract]
BS EN 50289-3-4
Communication cables, Electric cables, Communication transmission lines, Mechanical testing, Tensile strength, Tensile testing, Elongation, Shrinkage, Shrinkage tests, Electrical insulating materials, Sheathed cables, Insulated cables, Cable sheaths
1153
Case study
Extruded Seal Deflection, Insertion and Extraction Forces
Requirement
Vintech Industries Inc. is a global Tier 2 supplier of thermoplastic extrusion components to the automotive and non-auto RV industry.
1154
Case study
Synthetic sports surface tuft binding
Customised engineering example
Test method standard BS ISO 4919 applies to the tuft withdrawal force of carpets.
1155
Case study
Torque tester for windows and sunroof controls
Requirement
The customer requested a portable system which would quickly and easily allow him to test the torque required to open and close windows in a car.
1156
Case study
Box-forming and edge crush strength of cartons
Customised engineering example
The Box Crush Test (BCT) is commonly used to assess the effect of applying an axial top-load force upon the flat sides of carton boxes to simulate stacking them in a warehouse or during transportation.
1157
Case study
Couple de dévissage de capsules Stelvin® ROPP sur bouteille de vin
Exigence
L'emballage du vin a une grande influence sur la qualité du produit livré au client. Traditionnellement, la méthode de fermeture consiste en un bouchon de liège naturel ou, plus récemment, en synthétique.
1158
Case study
Syringe plunger breakaway and glide force
Customised engineering example
The majority of syringes are single-use, disposable and manually-operated.
1160
[Page extract]
ASTM D2979
This test method covers measurement of the pressure-sensitive tack of adhesives.
1161
Case study
Police force manual handling and protective clothing
Requirement
A major UK police force requires all new recruits to pass a ‘Job Related Fitness Test’ (JRFT), to ensure they are able to meet the taxing physical demands of the role. Armed officers must undergo yearly re-assessment.
1162
Case study
Vérification d'étalonnage du couplemètre pour essai de vissage & dévissage
Exigence
Le client dispose de plusieurs coulemètre Tornado et souhaite effectuer des contrôles réguliers de vérification d'étalonnage sans qu'il soit nécessaire de renvoyer les unités à Mecmesin ou à un laboratoire agréé.
1163
[Page extract]
BS EN ISO 22254
ISO 22254:2005 specifies a test method for determining the resistance of the tufted portion of manual toothbrushes to deflection. This could be used to derive a stiffness - a factor which has been of great concern to consumers and manufacturers.
1164
Case study
Essais de traction et de compression pour l'enseignement de la résistance de matériau
Exigence
Le département de bio-ingénierie de l'Imperial College London a été une organisation pionnière dans la formulation de cette discipline et est aujourd'hui le principal établissement du genre au Royaume-Uni.
1165
Case study
Force de déchirement de filet de pêche selon ISO1805 et ISO1806
Exigence
Les filets de pêche sont l’un des outils clés de la pêche commerciale et il existe de nombreux types de filets actifs et passifs disponibles.
1166
Case study
Cap removal test of plastic vial
Requirement
The customer approached Mecmesin with a specification to pull-off the cap of a pharmaceutical phial. The test equipment needed to be simple to use and able to perform repeatable tests.
1167
Event
Webinar: Adhesion/Peel strength testing
There is a reason people reach for duct tape as a fix for almost everything – adhesion strength.
From busted pipes to ripped furniture, the preference for a solution that “does not easily peel off” is the guiding principle for manufacturers.
1168
[Page extract]
ISO 594-1
Specification of the requirements for conical (Luer) fittings for use with hyperdemic syringes and needles and with certain other apparatus for medical use such as transfusion and infusion sets.
1169
Case study
PET screen protector release liner peel testing
Requirement
Manufacturers of products which include a critical screen surface, generally apply a plastic film as protection during assembly, packing and transit to the end customer.
1170
Event
Webinar: Essentials of Adhesion/Peel strength testing
There is a reason people reach for duct tape as a fix for almost everything – adhesion strength.
1171
[Page extract]
CETIE Guide 12
This guide describes the five essential rules to be observed to properly crimp a pump with an aluminium ferrule on an FEA type glass finish used for perfumery, according to the EN 14854 standard and the Cetie document GME 40.05.
1172
[Page extract]
USP <381>
This chapter applies to closures used for long-term storage of preparations defined in the general test chapter Packaging and Storage Requirements á659ñ, Injection Packaging.
1173
Case study
Wall-mounted air freshener destructive loading evaluation
Requirement
The customer wished to apply a controlled load of 350N to a wall mounted air freshener, replicating the effect of a child standing on it. The load needed to be applied in turn to 4 different planes on the product, e.g.
1174
[Page extract]
SAE J1701
This SAE Information Report is provided as an advisory guide. Individual application discretion is recommended. The content has been presented as accurately as possible, but responsibility for its application lies with the user.
1175
Event
Needle Sharpness & Puncture Resistance Testing
Hypodermic needles are tested to determine how their design influences the ease of insertion into the skin in order to prevent patient pain and skin trauma.