Search results
2626
[Page extract]
ASTM D5179-16
ASTM D5179 is a test method for determining organic coatings adhesion to a plastic substrate. It can be used to evaluate the adhesion (pull-off strength) of various coating/substrate combinations e.g. paint and varnish.
2627
[Page extract]
BS EN 14372
This document establishes minimum safety requirements and specifies appropriate test methods for children’s cutlery and feeding utensils designed for the use of children aged up to 3 years, with or without parental supervision.
2628
[Page extract]
ASTM D3472
This test method covers the measurement of the torque developed when Type IA child-resistant closures are rotated in the counter-clockwise direction.
2629
[Page extract]
Special compression fixtures
Special compression fixtures have been specially designed to meet the challenges of a particular application.
2630
[Page extract]
ASTM D747-10
ASTM D747 is used to determine the flexibility of plastics by means of a cantilever beam.
2631
[Page extract]
BS EN ISO 11608-3
Medical equipment, Medical instruments, Parenteral infusion equipment, Injection instruments, Injection guns, Syringes, Drug administration, Measuring cylinders, Containers, Performance testing, Performance, Leak tests, Design, Dimensions
2632
[Page extract]
*corp 01M-01-216
To determine the maximum force required to rupture (break) a woven fabric – Rugby only
2633
[Page extract]
ISO 9073-7
Specifies a method for the determination of the bending length of nonwovens. Gives an equation for calculating the flexural rigity of the fabric from the bending length. Does not apply to composites and laminates.
2634
[Page extract]
ISO 527-3
ISO 527-3 specifies the conditions for determining the tensile properties of plastic films or sheets less than 1 mm thick, based upon the general principles given in ISO 527-1.
2635
[Page extract]
ISO 15359
This International Standard specifies, a friction-testing method based on the horizontal plane principle, and the procedure for the determination of the static coefficient of friction before, and static and kinetic coefficients of friction after, a spec
2636
[Page extract]
BS 2782-3: 360C
BS 2782-3: Method 360C specifies a test method for testing the tear resistance of plastics film and sheeting by the initiation method
2637
[Page extract]
BS 1726-1
Provides guidance on methods of specifying and tolerancing hot coiled compression springs, and cold coiled springs that fall outside the size range limits specified in BS EN 15800.
2638
[Page extract]
ASTM D3354
ASTM D3354 is a test method that provides quantitative information on the degree of blocking i.e. unwanted adhesion between layers of plastic film.
2639
[Page extract]
BS EN 12814-1
BS EN 12814-1 is a bend test method for testing welded joints of thermoplastics semi-finished products.
2640
[Page extract]
BS EN 12242
The BS EN 12242 test method is used to determine the peel strength of a touch and close (also known as “hook and loop”) fastener through a 180° peel test that is able to determine average peel and the peel strength characteristics of the product for a g
2641
[Page extract]
BS ISO 4919
Specifies a method for determination of tuft withdrawal force and is applicable to all carpets with a cut or loop pile yarn structure.
2642
[Page extract]
BS EN ISO 13934-1
Part 1 of ISO 13934 specifies a procedure to determine the maximum force and elongation at maximum force of textile fabrics using a strip method.
2643
[Page extract]
BS EN ISO 1856
BS EN ISO 1856 is a test method that specifies three methods for determining the compression set of flexible cellular materials and applies only to latex and polyurethane foams of thickness greater than 2 mm.
2644
[Page extract]
ISO 1924-3
Specifies a method for measuring the tensile strength, strain at break, tensile energy absorption and tensile stiffness, using a testing machine operating with a constant rate of elongation (100 mm/min).
2645
Case study
Kosmetikdose Label Peeling
Beispiel für kundenspezifisches Engineering Das Testen der Haftfestigkeit von Verpackungsetiketten, die in der Postproduktionsphase aufgebracht wurden, ist repräsentativer für ihre Leistung als in der Etikettenproduktionsphase.
2646
[Page extract]
ISO 4587
Specifies a method for determining the tensile lap-shear strength of rigid-to-rigid bonded assemblies using a standard specimen under specified conditions of preparation and testing. This test procedure does not provide design information.
2647
[Page extract]
ASTM D6049-03
This test method is capable of measuring and characterizing the rheological behavior (viscosity and elasticity) of unvulcanized raw rubbers and rubber compounds, relating to the macro structure of rubber polymers (average molecular weight, molecular wei
2648
[Page extract]
ASTM D7084-04
1.1 This test method covers the determination of bulk crush strength of a bed of formed catalyst particles 1⁄32 to 3⁄16 in.
2649
[Page extract]
ISO 11607-1
Specifies the requirements and test methods for materials, preformed sterile barrier systems, sterile barrier systems and packaging systems that are intended to maintain sterility of terminally sterilized medical devices until the point of use.