Search results
2051
Test Frame
OmniTest test frame (single column)
OmniTest test frame
A single-column motorised test frame designed to apply tensile, shear, flexural and compressive forces from 2 N right up to a capacity of 7.5 kN (1686 lbf).Its versatile construction makes it perfectly suited for testing all kinds of…
2052
[Page extract]
BS ISO 5893
ISO 5893 specifies requirements for tensile-testing systems operating at constant rate of traverse and suitable for testing rubbers, plastics and adhesives, although any one system may only be applicable to a narrower range of materials.
2053
[Page extract]
Why Mecmesin for breakaway torque testing?
Mecmesin offers an unmatched combination of reliability, support, and industry insight:
2054
Case study
Test di compressione della bustina
Requisiti Comprimere sei bustine di ketchup o maionese fino a quando si è verificato un guasto alla confezione. La forza di compressione di picco era richiesta come risultato del test.
2055
Case study
Carta da filtro per test di buccia a 90 gradi
Esempio di ingegneria personalizzato Le maschere a rullo mobile vengono regolarmente utilizzate per testare i laminati in cui il foglio di supporto è rigido e il foglio di rivestimento flessibile (ad es. Carte di sicurezza)
2056
Case study
Test di penetrazione del cartongesso per prestazioni e durata
Requisiti Saint-Gobain (British Gypsum) è leader nella progettazione; produzione e distribuzione di materiali per la costruzione; mercati industriali e di consumo e sono il più grande distributore europeo di materiali da costruzione.
2058
Case study
Test di coppia chiusure di prodotti di bellezza
Requisiti Un produttore di una vasta gamma di prodotti per la cura della pelle, dei capelli, del trucco e del sole con sede in Grecia doveva sostituire i loro obsoleti tester di coppia con tester di coppia digitali aggiornati per garantire la
2059
[Page extract]
Coppia di strisciamento
Il test della coppia di serraggio è un metodo specializzato utilizzato per valutare le prestazioni e la sicurezza di chiusure e connettori filet
2060
[Page extract]
resistenza allo scoppio (rottura della lastra)
La resistenza allo scoppio è la capacità di un materiale o di un prodotto di mantenersi in continuità quando è sottoposto a pressione.
2061
[Page extract]
Allungamento e recupero
I test di allungamento e recupero sono un processo fondamentale nella scienza dei materiali, utilizzato per misurare quanto un materiale può allungarsi sotto un determinato carico e quanto efficacemente ritorna alla sua forma originale una volta rimossa
2062
[Page extract]
Shear Modulus Guide
Understanding how a material behaves under sliding or twisting forces is essential when selecting the right component for mechanical or structural performance.
2063
[Page extract]
Guida al modulo di taglio
La comprensione del comportamento di un materiale in presenza di forze di scorrimento o di torsione è essenziale per la scelta del componente giusto per le prestazioni meccaniche o strutturali.
2064
Event
Mecmesin Webinar: Introduction to consumer packaging testing
In the competitive world of consumer goods, damaged packaging isn't just a financial setback—it can tarnish your brand's reputation.
Customers are far less likely to choose a product with compromised packaging or one that arrives damaged due
2065
Sensor
Sensori - tester dei materiali
sensori I sistemi di prova dei materiali OmniTest e MultiTest-dV utilizzano la gamma di sensori di carico avanzati (ELS) di precisione ad alta risoluzione di Mecmesin per registrare carichi di trazione e compressione. ELS Una cella di carico di…
2066
Accessory
Multi-Jaw Grip, 500 N, 10-32 UNF
432-420
Used in tension tests the Multi-Jaw Grip is for holding round and irregularly shaped specimens by clamping on the outer surface or under a 'head'.
By turning the body of the grip the claw-type jaws can be opened and closed to get a secure grasp on a…
2067
Accessory
QC Type B Adapter, 20 mm F to M12 fixing bolt, c/w pin
432-283
QC Female Sleeve c/w cross-pin with M12 Fixing Bolt:
Converts a non-QC type grip into a QC type for quick interchange of grips. Fits to loadcells with M12 female thread (eg. ILC-S 2500N and ILC-S 5000N).
2068
Accessory
Adapter, 10 kN, M10 to M12, M to M
432-335
Male-to-male Adapter
Allows a grip to be connected to a force gauge/loadcell or test stand where thread connections are different.
2069
Accessory
Extension Rod with thumbwheel, 30 mm, 500N, M6 to 10-32 UNF
432-007
Extension rod 30mm long having 10-32 UNF female to M6 male threads.
Fitted with knurled thumbwheel for locking accessory in correct orientation.
2070
Accessory
Test Hook (small), 50 N, 10-32 UNF
432-118
Small Fixed Hook fitted with 10-32 UNF female thread. Used for general purpose tension tests.
2071
Accessory
Radiused Probe - 8 mm, 500 N, 10-32 UNF
432-354
Radiused Probes are used to perform penetration or puncture tests on a wide range of products.
Aspects measured include firmness and ripeness of cosmetics, medical gels and foodstuffs.
6mm diameter at the tip rising to 8mm outer diameter of the probe.…
2072
Accessory
3-Point Bend Jig, 2.5 kN, Aluminium, base plate
432-151
432-151 :- a simple 3-point bend jig supplied as standard with a 5mm radius upper anvil (M6 female thread connection) and two adjustable lower anvils also of 5mm radius. Lower support beam is fitted to a base plate suitable for Mecmesin motorised test…
2073
Accessory
Compression Plate, Rubber-Faced, 50 mm, 10-32 UNF
432-220
50mm nickel-plated compression plate featuring a rubber layer, which helps to prevent damage from metal-to-metal contact during a compression test. Fitted with 10-32 UNF female thread. Nickel-plated compression plates are resistant to rusting.
2074
Accessory
Lightweight Vice Grip - Double Action, 100 N, Opening 0-8mm, 10-32 UNF
Mec227
MEC 227 (body only):
A Lightweight Vice Grip providing free adjustment of both jaws, allowing them to be aligned around the central axis to accommodate tensile testing of both symmetrical and asymmetrical specimens.
Rated to 100 N in tension with an…
2075
Accessory
Adapter, 500N, M6 to M6, F to F
432-334
Female-to-female Adapter