Search results
1451
Accessory
Rubber jaws for Mec227 Lightweight Vice Grip, 100 N, 10 x 25mm
Mec227-BG25
Rubber-faced Jaws (10mm x 25mm) - nickel-plated having 1mm thick layer of nitrile rubber coating.
Opening span = 0 - 6mm.
For fragile samples, which may get weakened by pinching at the contact-edge of the grip. (e.g. thin films, filaments, fibres and…
1452
[Page extract]
ASTM D3578
Scope... 1.1 This specification describes certain requirements for natural rubber gloves used in conducting medical examinations and diagnostic and therapeutic procedures. It also covers natural rubber gloves used in handling contaminated medical
1453
Accessory
Wave jaws for Mec240k Medium Vice Grip, 2.5 kN, 30 x 100 mm
Mec240k-BW100
Wave Jaws (30mm x 100mm) - nickel-plated having a hardened steel surface of 5mm tall waves.
For flexible but slippy materials which need more surface contact to secure a good grip (e.g. textiles, fabrics and tissues).
Supplied as 0.5 set = 2 jaws (left…
1454
Case study
Test d'extraction des 2 parties pour les pièces de 1 et 2 euros
Exigence
Le client devait connaître la force nécessaire pour extraire la partie interne des pièces de 1 et 2 euros de leurs parties extérieures.
1455
Case study
Cosmetics tin label peel
Customised engineering example
Testing the adhesive peel strength of packaging labels applied at the post-production stage is more representative of their performance than at the label production stage.
1456
[Page extract]
Applications of tear testing equipment
Tear testing is applied in multiple sectors:
1457
[Page extract]
BS EN ISO 19011:2011
Provides the fundamental knowledge needed for auditing management systems and has been expanded to reflect modern thinking and the intricacies of auditing multiple management system standards (MSS).
1458
[Page extract]
Custom-fit material testing services
Tailored fixtures and adaptations
Accurate testing often depends on the right fixture design.
1459
[Page extract]
SAE USCAR-21-4
This specification defines test methods and requirements for validation of solderless crimped connections.
1460
Accessory
Diamond coated jaws for Mec154 Heavy-duty Vice Grip, 20kN, 40 x 100 mm
Mec154-BD100
Diamond Jaws (40mm high x 100mm wide) - nickel-plated having clamping surface coated with synthetic diamonds.
Opening span = 0 - 30 mm.
For materials which need a “bite” to secure a good grip (e.g. soft metals {aluminium, copper, soft steel, paper and…
1461
Accessory
Pyramid (serrated) jaws for Mec154 Heavy-duty Vice Grip, 20kN, 40 x 100 mm
Mec154-BP100
Pyramid Jaws (40mm high x 100mm wide) - nickel-plated having a surface of hardened steel pyramids of 1.2mm tall.
Opening span = 0 - 13 mm.
For materials which need a “bite” to secure a good grip (e.g. soft metals {aluminium, copper, soft steel, paper…
1462
[Page extract]
FAQs related to compressive strength testing
What is compressive strength?
1463
Accessory
Wave jaws for Mec154 Heavy-duty Vice Grip, 10kN, 60 x 200 mm
Mec154-BW200
Wave Jaws (60mm x 200mm) - nickel-plated having a hardened steel surface of 5mm tall waves.
Opening span = 0 - 22 mm.
For flexible but slippy materials which need more surface contact to secure a good grip (e.g. textiles, fabrics and tissues).…
1464
Accessory
Rubber jaws for Mec227 Lightweight Vice Grip, 250 N, 10 x 50 mm
Mec227-BG50
Rubber-faced Jaws (10mm x 50mm) - nickel-plated having 1mm thick layer of nitrile rubber coating.
Opening span = 0 - 4mm.
For fragile samples, which may get weakened by pinching at the contact-edge of the grip. (e.g. thin films, filaments, fibres and…
1465
Accessory
Blank (smooth) Inset Jaws for MEC9 Thin Wire Grip, 2.5 kN
Mec9-EB
MEC9-EB Blank Jaws
Blank (smooth) inset jaws of 37 mm height x 15 mm width, 0.5 set. For fitting into the carrier of the MEC9 Thin Wire Grip.
Used when jaws require a specific surface to be machined onto them. Alternatively for affixing an abrasive…
1466
[Page extract]
Speak to an Expert
Compressive modulus testing is essential for confirming stiffness, durability, and compliance in materials used across construction, aeros
1467
Accessory
Rubber jaws for Lightweight Pneumatic Plane Grip, 200 N, 25 x 50mm
Mec94-BG50
Rubber-faced Jaws (25mm x 50mm) - nickel-plated having 1mm thick layer of nitrile rubber coating.
Opening span = 0 - 18mm.
For fragile samples, which may get weakened by pinching at the contact-edge of the grip. (e.g. thin films, filaments, fibres and…
1468
[Page extract]
ASTM D1710
Among tests for electrical and dimensional (temperature) stability, includes methods for tensile characteristics.
1469
Accessory
Wave jaws for Mec11-20 Scissor Grip, 20 kN, 25 x 50 mm
Mec11-20-BW
Wave Jaws (25mm x 50mm) - nickel-plated having a hardened steel surface of 5mm tall waves.
For flexible but slippy materials which need more surface contact to secure a good grip (e.g. textiles, fabrics and tissues).
Supplied as 0.5 set = 2 jaws (left…
1470
Case study
Bow attachment pull-off test on clothing
Requirement
The customer was a supplier to major UK clothing retailer Marks & Spencer, who stipulate that all fasteners and attachments must be tested to failure.
1471
[Page extract]
Step-by-step guide to conducting a CMT test
Prepare the specimen - Cut to size with clean edges, ensuring flutes remain undamaged, and condition as per the standard.
Calibrate the equipment - Check the load cell and platen alignment.
1472
Accessory
Rubber jaws for Mec227 Lightweight Vice Grip, 100 N, 10 x 100 mm
Mec227-BG100
Rubber-faced Jaws (10mm x 100mm) - nickel-plated having 1mm thick layer of nitrile rubber coating.
Opening span = 0 - 4mm.
For fragile samples, which may get weakened by pinching at the contact-edge of the grip. (e.g. thin films, filaments, fibres and…
1473
Case study
Railcar spring testing
Requirement
Seoul Metropolitan Railway Transit Corporation required a system for testing a variety of springs in their electric railcars. The springs range in size from 3mm to 100 mm in diameter.
1474
Case study
Forces d'insertion et de retrait de cosse électrique
Exemple d'ingénierie sur mesure
Les cosses électriques plate à oeillet, femelle ou à embout à sertir (également appelés «cosses plates») doivent offrir un ajustement ferme mais pratique.
1475
Case study
Smoke grenade canister integrity
Customised engineering example
A manufacturer of smoke grenades required a means of testing the cap pull-off strength. The particular challenge was to grip the smooth metal cylinder for up to 5 kN of pulling force.