Search results
1601
[Page extract]
AEC Q200-005
This specification establishes the procedure and criteria to determine the ability of surface
mounted device terminations and seals to withstand bending, flexing and pulling forces which
1602
Event
Needle Sharpness & Puncture Resistance Testing
Hypodermic needles are tested to determine how their design influences the ease of insertion into the skin, patient pain and skin trauma.
1604
[Page extract]
ASTM D3044
This test method covers determination of the shear modulus of wood-based structural panels associated with shear distortion in the plane of the panels. The method is applicable to all types of wood-based structural panels.
1605
Event
Coefficient of Friction (COF) Testing
Coefficient of Friction (COF) testing measures the static and kinetic friction values to help determine the quality of the final product.
1606
[Page extract]
ASTM C403/C403M
This test method covers the determination of the time of setting of concrete, with slump greater than zero, by means of penetration resistance measurements on mortar sieved from the concrete mixture.
1607
[Page extract]
ASTM F628-12e3
This specification covers coextruded acrylonitrile-butadiene-styrene (ABS) plastic drain, waste, and vent pipes made to Schedule 40 iron pipe sizes (IPS) with concentric inner and outer solid ABS layers and a closed-cell cellular ABS core.
1608
[Page extract]
ASTM D695-15
ASTM D695 is a test method used to determine the mechanical properties of unreinforced and reinforced rigid plastics, including high-modulus composites, when loaded in compression at relatively low uniform rates of straining or loading.
1609
[Page extract]
ASTM D3039 / D3039M
ASTM D3039 determines the in-plane tensile properties of polymer matrix composite materials reinforced by high-modulus fibers. A number of calculations can be made including ultimate tensile strength, ultimate tensile strain, tensile chord modulus of
1610
Event
Materials Testing: Theory and Practice Pt. 1
Materials testing is often the last step in the manufacturing process. Yet, quality is the result of both the process and the material. If the material that goes into the product is inadequate or defective, then the product may be deficient or faulty.
1611
[Page extract]
ISO 11070
Specifies requirements for introducer needles, introducer catheters, sheath introducers, guidewires and dilators supplied in sterile condition and intended for single use in conjunction with intravascular catheters specified in ISO 10555-1.
1612
[Page extract]
ISO 8510-1
Particularly suitable for use with less flexible adherends for which a 180 ° peel test is not suitable because the adherends crack, break or delaminate. A bonded assembly of two adherends is prepared using the adhesive under test.
1613
Event
Fundamentals of Food Texture Testing
Texture cannot be controlled unless it is measured in a consistent and repeatable manner.
1614
[Page extract]
ISO 2439
The indentation hardness of flexible cellular materials is a measure of their load-bearing properties.
1615
[Page extract]
EN 149
EN149 specifies minimum requirements for filtering half masks as respiratory protective devices to protect against particles except for escape purposes.
1616
[Page extract]
BS 5338
Recommendations on materials, basic design factors, component design, working practice, inspection. Appendices on mechanical properties and dimensional stability.
1617
Event
Live Demonstration: Face mask strength testing & Syringe plunger breakaway force testing
Medical device testing ensures patient safety, regulatory compliance, performance, quality, usability, claims examination, and post-market safety.
1618
[Page extract]
EN 22872
EN 22872 specifies two methods for testing complete, filled transport packages for compression resistance.
1619
[Page extract]
BS EN ISO 9001
ISO 9001 has been revised to reflect the many changes in the way we now do business – new technology, greater access to information, higher customer expectations, globalization and increasing importance of service industries.
1620
[Page extract]
ASTM D1335
Test Method D1335 for tuft bind of pile yarn floor coverings is being used for acceptance testing of commercial shipments. Comparative tests as directed in 5.1.1 may be advisable. […]
1621
[Page extract]
ASTM D6175-03
5.1 This test method is intended to provide information on the ability of an extruded catalyst to retain physical integrity during use.
1622
[Page extract]
ASTM F2132-01
This specification provides the performance requirements and associated test procedures for the puncture resistance of materials used in the construction of containers for discarded medical needles and other sharps.
1623
[Page extract]
ISO 13954
ISO 13954 describes a peel test method for determining the decohesive resistance of polyethylene electrofusion socket assemblies for use in the distribution of fluids.
1624
[Page extract]
*corp Ford DSEU
Test method covering measurement of door slam energy for Ford Chenai, India. Shows Mecmesin loadcell, display and special gripping fixtures. Note: Diagram shows a rigid link bar, which was later replaced by a flexible bungee connection.