Tensile Testing: Basics, Tips and Trends
Have you ever wondered if the seatbelt in your vehicle is strong enough to restrain you in a collision? How about the average person pulling the cork out of a wine bottle?
252
Event
Pull Force and Break Strength Testing
Whether it is medical tubing, plastic straws, copper wire or zip ties, pull force and break strength testing is critical not only to production quality but also to consumer safety.
253
Event
Understanding Adhesion Strength: 180 Degree Peel Test
Across many households and industries, consumers have developed a strong preference for and confidence in ‘Duct Tape’ for all types of uses and applications. This is mainly due to the adhesion strength.
254
[Page extract]
EN TS 15945
The purpose of DD CEN/TS 15945 is to specify test methods to evaluate the ease of opening of consumer packages, in order to improve easy access to the contents. For packages regulated for safety or similar reasons, e.g.
255
[Page extract]
BS EN 60793-1-31
Optical fibres, Fibre optics, Optical communication systems, Fibre optic cables, Electronic equipment and components, Optical measurement, Test methods, Environmental testing, Tensile strength, Tensile testing, Temperature, Specimen preparation
256
[Page extract]
AEC Q200-005
This specification establishes the procedure and criteria to determine the ability of surface
mounted device terminations and seals to withstand bending, flexing and pulling forces which
257
[Page extract]
BS EN 60794-1-21:2015+A1
This part of IEC 60794 applies to optical fibre cables for use with telecommunication equipment and devices employing similar techniques, and to cables having a combination of both optical fibres and electrical conductors.
258
[Page extract]
PD CEN/TR 17394-1
This document provides requirements for security of attachment for clothing components of infant clothing.
259
Event
Cap Closure and Removal Torque Testing
The primary objective for measuring and analyzing the torque characteristics of a container cap is to accurately determine not only the quality of the part or process, but also the root cause of a wide variety of defects.
260
Event
Needle Sharpness & Puncture Resistance Testing
Hypodermic needles are tested to determine how their design influences the ease of insertion into the skin in order to prevent patient pain and skin trauma.
261
[Page extract]
BS EN ISO 7864
BS EN ISO 7864:2016 specifies requirements for sterile hypodermic needles for single use of designated metric sizes 0,18 mm to 1,2 mm.
262
[Page extract]
BS EN 50081-1
This standard for emission requirements applies to electrical and electronic apparatus intended for use in the residential, commercial and light-industrial environment, as described in clause 5, for which no dedicated product or product-family emission
263
[Page extract]
BS EN 1263-1
Safety nets, Restraint systems (protective), Construction equipment, Safety devices, Building sites, Occupational safety, Performance, Man-made fibres, Polyamide fibres, Polyolefin fibres, Ropes, Performance testing, Mechanical testing, Tensile testing,
264
[Page extract]
ASTM D 2979
1.1 This test method covers measurement of the pressure sensitive tack of adhesives.
265
Event
Compressive Crush Force Testing
This webinar will focus on identifying and troubleshooting variables that impact compressive force testing, setting up repeatable compression force tests and establishing consistent testing standards for your products.
266
[Page extract]
ASTM F2606-08
This guide can be used to obtain force versus deflection or midspan bending moment versus midspan curvature curves for stents and stent systems subjected to three-point bending conditions.
267
Event
Tensile Testing: Basics, Tips, & Trends
Have you ever wondered if the seatbelt in your vehicle is strong enough to restrain you in a collision? How about the average person pulling the cork out of a wine bottle?
268
[Page extract]
ISO 11607-1
Specifies the requirements and test methods for materials, preformed sterile barrier systems, sterile barrier systems and packaging systems that are intended to maintain sterility of terminally sterilized medical devices until the point of use.
269
Event
180 Peel Testing Webinar (9 Feb. 2022)
Across many households and industries, consumers have developed a strong preference for and confidence in ‘Duct Tape’ for all types of uses and applications. This is mainly due to the adhesion strength.
270
[Page extract]
BS EN 60352-2
Solderless connectors, Electric connectors, Crimped connectors, Electrical components, Electronic equipment and components, Electrical connections, Communication equipment, Crimping tools, Dimensions, Mechanical crimping, Dimensional measurement, Electr
271
[Page extract]
BS 7409
Lays out safety requirements for wheeled conveyances for one or more children. Does not cover wheeled conveyances designed for invalid children and does not specify requirments for accessories or products not designed for use with a chassis.
272
[Page extract]
ASTM D3474
This standard covers the calibration and use of torque meters of the type normally used in packaging applications.
273
[Page extract]
EN 149
EN149 specifies minimum requirements for filtering half masks as respiratory protective devices to protect against particles except for escape purposes.
274
Event
Tensile Testing: Extension, Elongation, Force & Failure
The primary objective for measuring and analyzing the the tensile force value of a product is to accurately determine one or more of these factors:
275
Event
Fundamentals of Compression Testing
How much force is required to register a command when you click your computer mouse?
How much force can a water bottle take before it collapses in its case under a stack?