Search results
201
Accessory
Pyramid (serrated) jaws for Mec83 U-Form Pneumatic Vice Grip, 5 kN, 40 x 100 mm
Mec83-BP100
Pyramid Jaws (40mm high x 100mm wide) - nickel-plated having a surface of hardened steel pyramids of 1.2mm tall.
Opening span = 0-10mm, 10-20mm or 20-30mm depending on which rod and piston are fitted to the Mec83 body.
For materials which need a “bite…
202
Accessory
Wave jaws for Mec240g U-Form Vice Grip, 5 kN, 30 x 80 mm
Mec240g-BW80
Wave Jaws (30mm x 80mm) - nickel-plated having a hardened steel surface of 5mm tall waves.
Opening span = see datasheet for various spans according to the grip body selected.
For flexible but slippy materials which need more surface contact to secure a…
203
Accessory
Pyramid (serrated) jaws for Mec83 U-Form Pneumatic Vice Grip, 5 kN, 40 x 60 mm
Mec83-BP
Pyramid Jaws (40mm high x 60mm wide) - nickel-plated having a surface of hardened steel pyramids of 1.2mm tall.
Opening span = 0-10mm, 10-20mm or 20-30mm depending on which rod and piston are fitted to the Mec83 body.
For materials which need a “bite”…
204
Accessory
Wave jaws for Mec240g U-Form Vice Grip, 5 kN, 30 x 100 mm
Mec240g-BW100
Wave Jaws (30mm x 100mm) - nickel-plated having a hardened steel surface of 5mm tall waves.
Opening span = see datasheet for various spans according to the grip body selected.
For flexible but slippy materials which need more surface contact to secure…
205
Accessory
Square Perforated Aluminium Compression Plate, 400 x 400 mm, QC-20 or QC-32 fitting
Mec36L-400-L6x20
MEC36L-400-L6x20
Square Compression Plate in aluminium featuring perforations to allow air release during testing - suitable for foam testing. Holes are 6mm diameter and spaced at 20mm intervals.
Dimensions: 400mm x 400mm.
Fitted with QC-20mm or 32mm…
206
Accessory
Rubber jaws for Mec83 U-Form Pneumatic Vice Grip, 5 kN, 60 x 200 mm
Mec83-BG200
Rubber-faced Jaws (60mm x 200mm) - nickel-plated having 1mm thick layer of nitrile rubber coating.
Opening span = 0-10mm, 10-20mm or 20-30mm depending on which rod and piston are fitted to the Mec83 body.
For fragile samples, which may get weakened by…
207
Accessory
Split Mandrel for Stelvin aluminium closure, pneumatic
PDV14181
Suitable for Stelvin aluminium closures.
Pneumatically-operated chuck complete with half-round jaws with wire-eroded faces, for use with Vortex Upper Fixing Plate (432-321). Supplied with pneumatic valves and tubes.
Specify closure diameter when…
208
Accessory
Wave jaws for Mec240g U-Form Vice Grip, 5 kN, 30 x 50 mm
Mec240g-BW
Wave Jaws (30mm x 30mm) - nickel-plated having a hardened steel surface of 5mm tall waves.
Opening span = see datasheet for various spans according to the grip body selected.
For flexible but slippy materials which need more surface contact to secure a…
209
Accessory
Square Perforated Aluminium Compression Plate, 200 x 200 mm, QC-20 or QC-32 fitting
Mec36L-200-L6x20
MEC36L-200-L6x20
Square Compression Plate in aluminium featuring perforations to allow air release during testing - suitable for foam testing. Holes are 6mm diameter and spaced at 20mm intervals.
Dimensions: 200mm x 200mm.
Fitted with QC-20mm or 32mm…
210
Accessory
Rubber jaws for Mec83 U-Form Pneumatic Vice Grip, 5 kN, 40 x 100 mm
Mec83-BG100
Rubber-faced Jaws (40mm x 100mm) - nickel-plated having 1mm thick layer of nitrile rubber coating.
Opening span = 0-10mm, 10-20mm or 20-30mm depending on which rod and piston are fitted to the Mec83 body.
For fragile samples, which may get weakened by…
211
Accessory
Wave jaws for Mec240g U-Form Vice Grip, 5 kN, 30 x 80 mm
Mec240g-BW80
Wave Jaws (30mm x 80mm) - nickel-plated having a hardened steel surface of 5mm tall waves.
Opening span = see datasheet for various spans according to the grip body selected.
For flexible but slippy materials which need more surface contact to secure a…
212
Accessory
Square Perforated Aluminium Compression Plate, 400 x 400 mm, QC-20 or QC-32 fitting
Mec36L-400-L6x20
MEC36L-400-L6x20
Square Compression Plate in aluminium featuring perforations to allow air release during testing - suitable for foam testing. Holes are 6mm diameter and spaced at 20mm intervals.
Dimensions: 400mm x 400mm.
Fitted with QC-20mm or 32mm…
213
[Page extract]
ASTM F2923
This specification establishes requirements and test methods for specified elements and certain mechanical hazards in children's jewelry.
214
Product
Automated torque tester
Vortex-i
876-009
The Vortex-i is a top of the range torque tester controlled by software running on a PC. Accurate, easy to use and optimised for measuring static torque up to 10 N.m.
The ultimate flexible solution for automated torque testing of a wide range of closures…
215
Case study
Car door closure effort
Requirement
When shutting car doors, users need to apply a certain force to initiate the movement and ensure a complete closure.
216
Case study
Actuation force of pump dispenser
Requirement
The customer manufactures a range of dispensing pumps for the cosmetic and beauty-care industry. A requirement was identified to measure the actuation force of the pump assembly and the pull-off force of the pump handle.
217
Case study
Rotating Vacuum Peel System
Requirement
Testing was required for a range of flexible plastic trays of the same dimension but with differing forms, containing biscuits and confectionary.
218
Case study
Measuring shear strength of loose building materials
Customised engineering example
The shear strength of compacted materials (e.g. soil and sand) can be awkward to test.
219
Page
Contact sales
Thank you for contacting our sales team
One of our Technical Sales Engineers or your local partner will be in touch soon.
220
Case study
Peel testing vacuum-formed containers
Customised engineering example
Semi-rigid thermoformed packaging, sealed by film or foil, is commonly tested by the '45-degree peel method'. This best represents how a person would open the package.
221
Case study
Festive lighting masonry anchorage strength checking
Requirement
A number of local councils in the United Kingdom have adopted a new code of practice for the Installation, Operation and Removal of Seasonal Decorations.
222
Case study
Euro coins extraction test
Requirement
The Spanish producer needed to find out the force to extract the inner filler of the 1 and 2 Euro coin from their outer ring.
223
Case study
Syringe pump calibrator
Requirement
Medical device manufacturers, Cardinal Health, supply a range of syringe pump infusion systems to hospitals.
224
Case study
Adhesion peel strength of COVID-19 tapes and stickers
Requirement
In the wake of the Covid-19 lockdown, there have been clear guidelines issued to businesses on keeping staff and customers safe.
225
Case study
Using a UTM as a calibration tool for loadcells
Requirement
When it comes to configuring and calibrating a loadcell in tension and compression this can be a time-consuming process, particularly when the loads concerned are too high to use a set of calibrated weights (also known as ‘masses’)