Search results
1126
Case study
Train sliding door slam force tester
Requirement
A portable device was specified for testing the force required to activate the inbuilt safety device when automatic doors close on trains.
1127
[Page extract]
ASTM D6049-03
This test method is capable of measuring and characterizing the rheological behavior (viscosity and elasticity) of unvulcanized raw rubbers and rubber compounds, relating to the macro structure of rubber polymers (average molecular weight, molecular wei
1128
Case study
Synthetic sports surface tuft binding
Customised engineering example
Test method standard BS ISO 4919 applies to the tuft withdrawal force of carpets.
1130
[Page extract]
MIL 22520-G
This specification covers the general requirements for crimping tools, accessories and inspection gages used for connecting removable contacts (such as; signal, power, coaxial, shielded, thermocouple, and filter pin contacts) coaxial connectors, shielde
1131
Case study
As vedações do tubo de alumínio perfuram o esforço de compressão
Requerimento Um dos maiores fornecedores de tubos de embalagem na Europa Central é especializado em recipientes de plástico laminado e tubos de alumínio para a indústria de cosméticos.
1132
[Page extract]
ASTM D2646
These test methods may be used for acceptance testing of commercial shipments; however, caution is advised because information about between interlaboratory precision is incomplete. Comparative tests as directed in 5.1.1 may be advisable.
1133
Case study
Teste de tração em materiais de calçados
Requerimento William Lamb Footwear é um dos principais distribuidores de calçados do Reino Unido.
1134
Case study
Car door closure effort
Requirement
When shutting car doors, users need to apply a certain force to initiate the movement and ensure a complete closure.
1135
[Page extract]
ASTM D3032
These test methods detail the standard procedures for testing hookup wire insulations including all components of the insulation system used on single insulated conductors or an assembly of single insulated conductors such as a cable bundle and harness
1136
Case study
Teste de força flip-cap
Requerimento Um sistema de teste repetível para verificar a força de abertura das tampas flip cap, acomodando 3 tampas de diâmetros diferentes com troca mínima de fixação.
1137
Case study
Teste de toque com evidência de violação
Requerimento O cliente fabrica tampas para a indústria de bebidas. Isso inclui tampas invioláveis usadas em águas minerais e outros refrigerantes.
1139
Case study
Teste de resistência à tração de correias de móveis
Requerimento Apoiado pela Casa Real do Castelo de Windsor, um estudante da Buckinghamshire New University estava investigando o desgaste e as propriedades de resistência da teia tradicional inglesa à base de juta, usada na construção e restaura
1140
[Page extract]
Ultimate Tensile Strength
What it is, how to measure it, and why it matters
Ultimate tensile strength (UTS) is a critical property used to determine how materials behave under tension. It defines the maximum stress a material can withstand before breaking.
1141
[Page extract]
Paper & Board
Paper and board are used in a wide range of applications and, as such, they undergo various stages of processing which place significant demands on their material strength.
1142
Case study
Teste de força de ruptura de fio-guia médico
Requerimento A empresa é fabricante de dispositivos e componentes médicos formados por fio, usados em dispositivos minimamente invasivos para aplicações cardiovasculares, endo e neurovasculares.
1143
Case study
Teste de tração de junta de vedação térmica de bolsa médica
Requerimento Rocket Medical PLC são designers e fabricantes premiados de dispositivos médicos para uma ampla gama de aplicações clínicas.
1144
Page
Calibração
A Mecmesin está comprometida em fornecer o mais alto nível de serviço pós-venda aos nossos clientes em todo o mundo. Para manter seu equipamento de teste de força e torque em condições de primeira classe, você sempre pode contar com nossa equipe de…
1145
Case study
Teste da força de fixação dos fechos com fio
Requisito
À medida que os consumidores, os fabricantes e os legisladores exigem embalagens mais ecológicas e que a utilização crescente de materiais recicláveis se torna comum, as atenções voltam-se para o humilde fecho de plástico.
1146
[Page extract]
Understanding compressive and tensile forces
Insertion and withdrawal testing focuses on two key force measurements:
1147
Accessory
Heavy-duty Vice Grip - Single Action, 20 kN, QC-20 fitting
Mec154-20
MEC 154-20 (body only - steel):
A Single-action Heavy-duty Vice Grip allowing one jaw to be manually set in a position to align a test specimen around the central axis. The other jaw is freely adjustable to mechanically clamp the specimen in place.…
1148
Accessory
Scissor Grip, 20 kN, QC-20 or QC-32 fitting
Mec11-20
MEC11-20 (Body only) :
Scissor-action grip rated to 20 kN fitted with either QC-20 or QC-32 connection.
Locking function allows the grip to remain open when inserting a specimen.
Spring tension provides enough clamping force to prevent the specimen…
1149
Accessory
Wave jaws for Mec154 Heavy-duty Vice Grip, 20kN, 40 x 100 mm
Mec154-BW100
Wave Jaws (40mm x 100mm) - nickel-plated having a hardened steel surface of 5mm tall waves.
Opening span = 0 - 30 mm.
For flexible but slippy materials which need more surface contact to secure a good grip (e.g. textiles, fabrics and tissues).…
1150
Accessory
Wave jaws for Mec240k Medium Vice Grip, 2.5 kN, 30 x 80 mm
Mec240k-BW80
Wave Jaws (30mm x 80mm) - nickel-plated having a hardened steel surface of 5mm tall waves.
For flexible but slippy materials which need more surface contact to secure a good grip (e.g. textiles, fabrics and tissues).
Supplied as 0.5 set = 2 jaws (left…