This Part of BS 5G 178 specifies the design requirements and tests for components and tools for the crimping of insulated and non-insulated terminals and splices to general purpose electrical cables or equipment wires for aircraft with conductors of copper, copper alloy, aluminium or aluminium alloy, in locations in which the stabilized conductor temperature does not exceed the value specified for the relevant type of cable.


The standard prescribes a series of tests to be performed in a defined sequence. These include:


Visual inspection of tooling, connectors and completed joints in correspondence with approved drawings.

Voltage drop test

Salt spray test

Load and temperature cycling

Tensile test





Test method


The tensile load test may be performed on its own or as part of the full range of test which should be conducted in the order given in the standard. Sufficient quantities of crimped joint should be made to fulfil the minimum number of replicates for the entire test sequence as planned.


Visually inspect the conductors, crimps and tooling to ensue all are in accord with their relevant approved drawings.

Form the crimped connection as detailed in the standard and in according to the manufactures instructions.

Follow the sequence of testing given with the prescribed number of test specimens for each stage.

For the tensile test, note the instruction to render the insulation support ineffective if this is required.

Test each sample by loading into the jaws/receptacle of the motorised tester and pulling the joint to destruction at a steady rate of 25 – 50 mm/min. Check that the pull-off load does not fall below the minimum values given in the standard.

電気ハーネス端子テスト

Case study
Mecmesin MultiTest 1-xの購入に非常に満足しています。これは、品質管理、システムの不可欠な部分になり、ツールを調整して、モータースポーツの過酷な環境で製品の信頼性を可能な限り確保できるようになりました。 。

ナイジェルバーバー、シニアエンジニア
キプロムモータースポーツ

BS 5G 178-1
現場での電気ハーネス圧着試験

電気ハーネス端子テスト

Mecmesin MultiTest 1-xの購入に非常に満足しています。これは、品質管理、システムの不可欠な部分になり、ツールを調整して、モータースポーツの過酷な環境で製品の信頼性を可能な限り確保できるようになりました。 。

ナイジェルバーバー、シニアエンジニア
キプロムモータースポーツ

Case study
現場での電気ハーネス圧着試験

専門家に相談する

製品について質問がありますか?今すぐテクニカルセールスエンジニアの1人に折り返し電話をリクエストしてください。