BS EN 61238-1
Electric connectors, Crimped connectors, Electric cables, Power cables, Electric conductors, Electric wires, Copper, Aluminium, Temperature, Classification systems, Type testing, Short-circuit current tests, Resistance measurement, Mechanical testing, T
327
[Page extract]
ASTM D2261
This test method covers the measurement of the tearing strength of textile fabrics by the tongue (single rip) procedure using a recording constant-rate-of-extension-type (CRE) tensile testing machine.
328
[Page extract]
ASTM F1306
ASTM F1306, is a test method, which permits flexible barrier films and laminates to be characterised for slow rate penetration resistance to a driven probe.
329
[Page extract]
BS EN 843-1
EN843-1 describes methods for determining the nominal flexural strength of advanced monolithic technical ceramic materials at ambient temperature.
330
[Page extract]
PSTC 101
These methods cover the measurement of the peel adhesion of pressure sensitive tapes.
331
[Page extract]
ASTM D5321-12
This test method covers a procedure for determining the shear resistance of a geosynthetic against soil, or a geosynthetic against another geosynthetic, under a constant rate of deformation.
332
[Page extract]
ASTM D695-15
ASTM D695 is a test method used to determine the mechanical properties of unreinforced and reinforced rigid plastics, including high-modulus composites, when loaded in compression at relatively low uniform rates of straining or loading.
333
[Page extract]
ISO 1924-2
Specifies a method for measuring the tensile strength, strain at break and tensile energy absorption of paper and board, using a testing machine operating at a constant rate of elongation (20 mm/min).
334
[Page extract]
TAPPI T 825
The flat crush test (1) is a measure of the resistance of the flutes in corrugated board to a crushing force applied perpendicular to the surface of the board under prescribed conditions.
335
[Page extract]
IEC 60598
IEC 60598-1 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V.
336
[Page extract]
*corp 01M-01-216
To determine the maximum force required to rupture (break) a woven fabric – Rugby only
337
[Page extract]
IEC 61210
IEC 61210:2010 applies to non-insulated flat quick-connect terminations consisting of a male tab of size 2,8 mm, 4,8 mm, 6,3 mm or 9,5 mm with hole or dimple detents and a mating female connector for use as either an incorporated or an integrated part o
338
[Page extract]
ASTM D1938
ASTM D1938 covers the determination of the force necessary to propagate a tear in plastic film and thin sheeting by a single-tear method. It rates the tear-propagation resistance of various plastic films and thin sheeting of comparable thickness.
339
[Page extract]
USP 1207.3
USP 1207.3 provides guidance on the integrity assurance of nonporous packages intended for sterile pharmaceutical products. Background instruction is provided on the topics of leaks, leakage rate, and package sealing/closure mechanisms
340
[Page extract]
ASTM D6109-19
ASTM D 6109 determines the flexural properties for any solid or hollow manufactured plastic lumber product of square, rectangular, round, or other geometric cross section that shows viscoelastic behavior.
341
[Page extract]
BS EN ISO 4624
Describes methods for determining the adhesion by carrying out a pull-off test on a single coating or a multi-coat system of paint, varnish or related product.
342
[Page extract]
BS EN 14704-1
Methods for testing using stripsof fabric in straight strip form or loops, which can be used to measure elasticity and related properties of fabrics, excluding narrow fabrics.
343
[Page extract]
ASTM D2659
ASTM D2659 determines the mechanical properties of blown thermoplastic containers under columnar crush conditions at a steady rate of compression. Any container, whether blown commercially or in the laboratory, may be used as the test specimen.
344
[Page extract]
CETIE Guide 12
This guide describes the five essential rules to be observed to properly crimp a pump with an aluminium ferrule on an FEA type glass finish used for perfumery, according to the EN 14854 standard and the Cetie document GME 40.05.
345
[Page extract]
ASTM d6108-19
ASTM D6108 covers the determination of the mechanical properties of plastic lumber and shapes, when the entire cross-section is loaded in compression at relatively low uniform rates of straining or loading.
346
[Page extract]
BS EN 12242
The BS EN 12242 test method is used to determine the peel strength of a touch and close (also known as “hook and loop”) fastener through a 180° peel test that is able to determine average peel and the peel strength characteristics of the product for a g
347
[Page extract]
TAPPI T 576
This test method decribes the procedure, using constant-rate-of-elongation, for determining three tensile breaking properties of towel and tissue: tensile strength, stretch, and tensi;e energy absorption.
348
[Page extract]
BS EN ISO 10555-5
Catheters, Cannulas, Sterile equipment, Parenteral infusion equipment, Medical instruments, Medical equipment, Disposable, Colour codes, Preferred sizes, Diameter, Syringes, Flow rates, Packaging, Tensile testing, Mechanical testing, Testing conditions,
349
[Page extract]
DIN EN 61238-1
Electric connectors, Crimped connectors, Electric cables, Power cables, Electric conductors, Electric wires, Copper, Aluminium, Temperature, Classification systems, Type testing, Short-circuit current tests, Resistance measurement, Mechanical testing, T