Search results
1376
[Page extract]
What is the box crush test?
The box crush test (BCT) is a widely used method for measuring the compressive strength of fibreboard packaging, particu
1377
Accessory
Pyramid jaws for Mec11-5 Scissor Grip, 5 kN, 20 x 50mm
Mec11-5-BP
Pyramid Jaws (20mm x 50mm) - nickel-plated having a surface of hardened steel pyramids of 1.2mm tall.
For materials which need a “bite” to secure a good grip (e.g. soft metals {aluminium, copper, soft steel, paper and board)
Supplied as 0.5 set = 2…
1378
[Page extract]
What is elongation at break?
Elongation at break measures how much a material can stretch before it fractures. Expressed as a percentage of the original gauge length, it is a key indicator of ductility and toughness.
1379
Accessory
Diamond coated jaws for Mec154 Heavy-duty Vice Grip, 20kN, 40 x 60 mm
Mec154-BD
Diamond Jaws (40mm high x 60mm wide) - nickel-plated having clamping surface coated with synthetic diamonds.
Opening span = 0 - 30 mm.
For materials which need a “bite” to secure a good grip (e.g. soft metals {aluminium, copper, soft steel, paper and…
1380
Accessory
Wave jaws for Mec154 Heavy-duty Vice Grip, 20kN, 40 x 100 mm
Mec154-BW100
Wave Jaws (40mm x 100mm) - nickel-plated having a hardened steel surface of 5mm tall waves.
Opening span = 0 - 30 mm.
For flexible but slippy materials which need more surface contact to secure a good grip (e.g. textiles, fabrics and tissues).…
1381
[Page extract]
PD CEN/TR 17394-1
This document provides requirements for security of attachment for clothing components of infant clothing.
1382
Case study
Glass syringe Luer lock attachment pull-off
Customised engineering example
Polycarbonate Luer Lock adapters are push-fitted to glass syringe nozzles with a friction fit. Quality assurance demands that they cannot come free under normal use.
1383
Accessory
Rubber jaws for Mec227 Lightweight Vice Grip, 250 N, 10 x 25mm
Mec227-BG25
Rubber-faced Jaws (10mm x 25mm) - nickel-plated having 1mm thick layer of nitrile rubber coating.
Opening span = 0 - 6mm.
For fragile samples, which may get weakened by pinching at the contact-edge of the grip. (e.g. thin films, filaments, fibres and…
1384
Accessory
Pyramid-faced jaws for 10 kN Wedge Grip, 40 x 34mm
MecS622-BP
Pyramid Jaws (40mm x 34mm) - nickel-plated having a surface of hardened steel pyramids of 1.2mm tall.
For materials which need a “bite” to secure a good grip (e.g. soft metals {aluminium, copper, soft steel, paper and board)
Supplied as 0.5 set = 2…
1385
Accessory
Pyramid (serrated) jaws for Mec154 Heavy-duty Vice Grip, 20kN, 40 x 60 mm
Mec154-BP
Pyramid Jaws (40mm high x 60mm wide) - nickel-plated having a surface of hardened steel pyramids of 1.2mm tall.
Opening span = 0 - 13 mm.
For materials which need a “bite” to secure a good grip (e.g. soft metals {aluminium, copper, soft steel, paper…
1386
[Page extract]
How to choose the right testing solution
Selecting the correct compressive strength testing solution involves considering factors such as material type, industry standards, testing precision, and equipment capabilities.
1387
Accessory
Wave jaws for Lightweight Pneumatic Plane Grip, 200 N, 25 x 50 mm
Mec94-BW50
Wave Jaws (25mm x 50mm) - nickel-plated having a hardened steel surface of 5mm tall waves.
Opening span = 0 - 16mm.
For flexible but slippy materials which need more surface contact to secure a good grip (e.g. textiles, fabrics and tissues).
Supplied…
1388
[Page extract]
ASTM D885/D885M-10a
These [comprehensive] test methods cover the testing of industrial filament yarns made wholly of manufactured organic-base fibers, cords twisted from such yarns, fabrics woven from such cords, and products that are made specifically for use in the manuf
1389
Accessory
Rubber jaws for Lightweight Pneumatic Plane Grip, 200 N, 25 x 25 mm
Mec94-BG25
Rubber-faced Jaws (25mm x 25mm) - nickel-plated having 1mm thick layer of nitrile rubber coating.
Opening span = 0 - 18mm.
For fragile samples, which may get weakened by pinching at the contact-edge of the grip. (e.g. thin films, filaments, fibres and…
1390
[Page extract]
Introduction to secant modulus
In material testing and engineering, understanding how a material responds to applied stress is essential for predicting performance, ensuring safety, and optimising design.
1391
[Page extract]
Introduction to short span compression tests
The short span compression test (SCT) is a mechanical testing method used to measure the compressive strength of materials over a very short span.
1392
Accessory
Diamond coated jaws for Mec227 Lightweight Vice Grip, 100 N, 10 x 50 mm
Mec227-BD50
Diamond Jaws (10mm x 50mm) - nickel-plated having clamping surface coated with synthetic diamonds.
Opening span = 0 - 8mm.
For materials which need a “bite” to secure a good grip (e.g. soft metals {aluminium, copper, soft steel, paper and board)…
1393
[Page extract]
MIL 22520-G
This specification covers the general requirements for crimping tools, accessories and inspection gages used for connecting removable contacts (such as; signal, power, coaxial, shielded, thermocouple, and filter pin contacts) coaxial connectors, shielde
1394
[Page extract]
ASTM F1306
ASTM F1306, is a test method, which permits flexible barrier films and laminates to be characterised for slow rate penetration resistance to a driven probe.
1395
Case study
Peel testing Ostomy bags
Requirement
Salts Healthcare, a leading manufacturer and supplier of health care products required a low capacity system for testing the integrity of their hydrocolloid products.
1396
[Page extract]
Industry applications
Rotational shear and torque strength tests are used in many sectors, including:
1397
Accessory
Mounting plate for QC-20 Male Post on 50 kN systems
432-622
Allows QC type C Adapter (20mm Male Post) to be fitted directly to the base of 50 kN test systems.
Used when QC-20 grips and fixtures are in long-term use on 50kN test stand.
Supplied with 6 screws of M6 thread.
1398
[Page extract]
ASTM F3014-14
1.1 This test method describes the procedure for penetration testing sharp and blunt needles used for the placement of surgical sutures. It only describes the test procedures (Phase 1) and does not define a test medium at this time.
1399
Accessory
Pyramid (serrated) jaws for 20 or 50 kN Wedge Grip, 50 x 35mm, 4 - 16 mm opening
Mec243-BP16
Pyramid Jaws (50mm high x 35mm wide) - nickel-plated having a surface of hardened steel pyramids of 1.2mm tall.
Jaw opening = 4 - 16mm.
For flat specimens of materials which need a “bite” to secure a good grip (e.g. soft metals {aluminium, copper, soft…