Search results
1376
[Page extract]
ISO 527-5
ISO 527-5 specifies the test conditions for the determination of the tensile properties of unidirectional fibre-reinforced plastic composites, based upon the general principles given in ISO 527-1.
1377
Event
Fundamentals of Compression Testing
How much force is required to register a command when you click your computer mouse?
How much force can a water bottle take before it collapses in its case under a stack?
1378
[Page extract]
BS EN ISO 9626
This International Standard specifies the dimensions, surface and mechanical properties of normal- and thin-walled tubing of designated metric sizes 3,4 mm to 0,3 mm, and of extra-thin-walled tubing of designated metric sizes 2,1 mm to 0,6 mm.
1379
Event
WestPack Trade Show
Lansmont - together with our sister brand Mecmesin - will be participating in the upcoming WestPack trade show!
1380
Event
Needle Sharpness & Puncture Resistance Testing
Hypodermic needles are tested to determine how their design influences the ease of insertion into the skin in order to prevent patient pain and skin trauma.
1381
[Page extract]
SAE USCAR-21-4
This specification defines test methods and requirements for validation of solderless crimped connections.
1382
[Page extract]
MIL 22520-G
This specification covers the general requirements for crimping tools, accessories and inspection gages used for connecting removable contacts (such as; signal, power, coaxial, shielded, thermocouple, and filter pin contacts) coaxial connectors, shielde
1383
[Page extract]
IEC 61210
IEC 61210:2010 applies to non-insulated flat quick-connect terminations consisting of a male tab of size 2,8 mm, 4,8 mm, 6,3 mm or 9,5 mm with hole or dimple detents and a mating female connector for use as either an incorporated or an integrated part o
1384
[Page extract]
ISO 9187-2
ISO 9187-2:2010 specifies materials, dimensions and requirements for forms of one-point-cut (OPC) ampoules (forms B, C and D) for injectables.
Ampoules complying with ISO 9187-2:2010 are intended for single use only.
1385
[Page extract]
ASTM D3470
This test method covers the determination of the force required to cause a downward-force-while-turning lug-finish closure to be rotated across the container finish lugs (strippage) without downward force being applied to the closure (Type IIA closures)
1386
[Page extract]
ASTM D6272-17
This test method covers the determination of flexural properties of unreinforced and reinforced plastics, including high-modulus composites and electrical insulating materials in the form of rectangular bars molded directly or cut from sheets, plates, o
1387
[Page extract]
ISO 6922
Specifies a method for determining the bond strength of a butt joint when subjected to tensile force. The method is applicable to all types of adhesives.
1388
[Page extract]
ASTM D885/D885M-10a
These [comprehensive] test methods cover the testing of industrial filament yarns made wholly of manufactured organic-base fibers, cords twisted from such yarns, fabrics woven from such cords, and products that are made specifically for use in the manuf
1389
[Page extract]
BS EN 12090
Thermal insulating materials, Thermal insulation, Construction materials, Shear testing, Shear strength, Shear stress, Specimen preparation, Formulae (mathematics), Test specimens, Test equipment, Testing conditions, Adhesives, Mechanical testing, Repor
1390
[Page extract]
SAE J174M
This test procedure is intended to provide a quality control method for checking torque-tension characteristics of non-prevailing torque type threaded steel fasteners 6 through 24 mm nominal diameters.
1391
[Page extract]
ASTM D6742 / D6742M
ASTM D6742 is the standard test method for tensile and compression testing of filled-hole polymer matrix composite laminates. It provides instructions for modifying open-hole tension and compression test methods to determine filled-hole tensile and com
1392
[Page extract]
ASTM F963-17
This specification relates to possible hazards that may not be recognized readily by the public and that may be encountered in the normal use for which a toy is intended or after reasonably foreseeable abuse.
1393
Event
Fundamentals of Compression Testing
How much force is required to register a command when you click your computer mouse?
How much force can a water bottle take before it collapses in its case under a stack?
1394
Event
Fundamentals of Compression Testing
How much force is required to register a command when you click your computer mouse?
How much force can a water bottle take before it collapses in its case under a stack?
1395
[Page extract]
SAE J174
This test procedure is intended to provide a quality control method for checking torque-tension characteristics of non-prevailing torque type threaded steel fasteners 1/4 through 1 in nomial diameters.
1396
[Page extract]
ASTM D4649-03
This guide covers recommended guidelines and test methods for the selection, specification, and use of stretch wrap films for unitizing, reinforcing, and palletizing for indoor environments.
1397
[Page extract]
ASTM E9-09
These test methods cover the apparatus, specimens, and procedure for axial-load compression testing of metallic materials at room temperature.
1399
Event
Webinar: Master Grips & Fixtures for Consistent Testing
When physically testing a material or component, the ability to apply load to a test specimen is important—but having the ability to apply that load correctly is just as crucial.
1400
[Page extract]
BS EN ISO 527-2
ISO 527-2 specifies the test conditions for determining the tensile properties of moulding and extrusion plastics, based upon the general principles given in ISO 527-1.